Calculate ACGIH machine capture CFM, duct friction loss, total static pressure (in. WG), and required cyclone motor horsepower.
ACGIH recommended capture CFM, optimal pipe sizes, and minimum air transport velocities:
| Machine Port | Min Capture Airflow | Recommended Duct Diameter | Target Duct Velocity | Friction Drop / 10' | Min Impeller Power |
|---|---|---|---|---|---|
| 10" Cabinet Table Saw | 650 CFM | 6.0" Main (4" Base + 2.5" Guard) | 3,820 FPM | ~0.42 in. WG | 2.0ā3.0 HP |
| 8"ā12" Parallelogram Jointer | 500 CFM | 5.0" or 6.0" Duct | 3,900 FPM | ~0.38 in. WG | 2.0 HP |
| 15"ā20" Thickness Planer | 785 CFM | 6.0" Smooth Spiral Pipe | 4,000 FPM | ~0.58 in. WG | 3.0 HP |
| 24"+ Wide Drum Sander | 850 CFM | 6.0" or 7.0" Duct | 4,320 FPM | ~0.72 in. WG | 3.0ā5.0 HP |
| Compound Miter Saw Hood | 600 CFM | 5.0" or 6.0" Duct | 3,850 FPM | ~0.40 in. WG | 2.0ā3.0 HP |
Main trunk velocity must stay between 3,800 and 4,200 FPM. Dropping below 3,500 FPM causes dust to fall out of the airstream and accumulate along horizontal runs.
Ribbed flexible PVC hose creates roughly 3 to 4 times the friction resistance of smooth spiral pipe of identical diameter.
High-pressure continuous separation unit matching your calculated static pressure curve.
View Matching Cyclone SystemsAirtight self-cleaning aluminum blast gates and quick-fit fittings sized for minimal resistance.
Browse Matching Duct HardwarePleated spun-bond canisters trapping microscopic hazardous silica and hardwood dust.
Shop HEPA Canister FiltersAffiliate Disclosure: As an Amazon Associate, this website earns from qualifying purchases made through referral links on this page at zero additional cost to you.
Workshop Safety & Engineering Disclaimer: Calculations are ventilation guidelines based on ACGIH models. Always check manufacturer fan curves (CFM vs. SP in. WG) and ground metal ductwork to prevent static discharge.